Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Can J Cardiol ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38642847

RESUMO

Cardiac implantable electronic devices (CIED) are often important for regulating cardiac rate and rhythm. Pacemakers and defibrillators are among the top 10 most-implanted medical devices, with >1.5 million devices implanted annually. While millions of patients have benefited with improved quality of life and survival, CIED-systems are increasingly complex and do not always perform according to expectations. Advisory notices communicate important information about the safety and performance of a medical device to healthcare providers and patients. Medical device recalls are common, with >35 unique device recalls in the past five years. From an ethical standpoint, CIED recalls highlight a range of considerations including the consent process, duty to report, how best to promote autonomous decision-making, trust in the healthcare system, as well as disproportionate impact of these considerations on equity-deserving groups. The purpose of the current article is to review and advise regarding the process around medical device advisory and recall, with a specific focus on clinicians caring for patients affected by these devices. We have sought the input of a lawyer, a patient advocacy group, and an ethicist to guide the clinical management of, and communications regarding, device recalls and advisories. Diligent surveillance and a clear, transparent patient consent process regarding these small but potentially serious device-anomalies is paramount in ensuring patients feel safe and informed. Meaningful patient engagement helps to ensure optimal communication and disclosure mechanisms before implant and throughout follow-up, accessibility of information both in the initial implant and recall action process, and trust in healthcare systems and providers.

2.
J Nucl Cardiol ; 34: 101786, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38472038

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Assuntos
Infecções Cardiovasculares , Endocardite , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Consenso , Tomografia Computadorizada por Raios X , Imagem Multimodal , Endocardite/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único
3.
Artigo em Inglês | MEDLINE | ID: mdl-38466252

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.

4.
Clin Infect Dis ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38466039

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.

5.
Heart Rhythm ; 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38466251

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.

6.
N Engl J Med ; 390(3): 212-220, 2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38231622

RESUMO

BACKGROUND: The Resynchronization-Defibrillation for Ambulatory Heart Failure Trial (RAFT) showed a greater benefit with respect to mortality at 5 years among patients who received cardiac-resynchronization therapy (CRT) than among those who received implantable cardioverter-defibrillators (ICDs). However, the effect of CRT on long-term survival is not known. METHODS: We randomly assigned patients with New York Heart Association (NYHA) class II or III heart failure, a left ventricular ejection fraction of 30% or less, and an intrinsic QRS duration of 120 msec or more (or a paced QRS duration of 200 msec or more) to receive either an ICD alone or a CRT defibrillator (CRT-D). We assessed long-term outcomes among patients at the eight highest-enrolling participating sites. The primary outcome was death from any cause; the secondary outcome was a composite of death from any cause, heart transplantation, or implantation of a ventricular assist device. RESULTS: The trial enrolled 1798 patients, of whom 1050 were included in the long-term survival trial; the median duration of follow-up for the 1050 patients was 7.7 years (interquartile range, 3.9 to 12.8), and the median duration of follow-up for those who survived was 13.9 years (interquartile range, 12.8 to 15.7). Death occurred in 405 of 530 patients (76.4%) assigned to the ICD group and in 370 of 520 patients (71.2%) assigned to the CRT-D group. The time until death appeared to be longer for those assigned to receive a CRT-D than for those assigned to receive an ICD (acceleration factor, 0.80; 95% confidence interval, 0.69 to 0.92; P = 0.002). A secondary-outcome event occurred in 412 patients (77.7%) in the ICD group and in 392 (75.4%) in the CRT-D group. CONCLUSIONS: Among patients with a reduced ejection fraction, a widened QRS complex, and NYHA class II or III heart failure, the survival benefit associated with receipt of a CRT-D as compared with ICD appeared to be sustained during a median of nearly 14 years of follow-up. (RAFT ClinicalTrials.gov number, NCT00251251.).


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Estimativa de Kaplan-Meier , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Eletrocardiografia , Seguimentos , Fatores de Tempo
9.
J Cardiovasc Electrophysiol ; 35(2): 240-246, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38047465

RESUMO

INTRODUCTION: The pivotal study of the extravascular implantable cardioverter-defibrillator (EV ICD) recently demonstrated primary efficacy and safety endpoints comparable to previous ICD systems. Patient experience with this novel device has not been reported. The current study examined the standardized patient-reported outcome (PRO) metrics of quality of life (QOL) and patient acceptance of the device. METHODS: The EV ICD Pivotal Study was a prospective, single-arm, nonrandomized, global, premarket approval trial. Patients completed the 12-Item Short Form Survey (SF-12) QOL surveys at baseline and at 6 months following implant. Additionally, patients completed the Florida Patient Acceptance Survey (FPAS) QOL survey at 6 months. RESULTS: From baseline to 6 months, patients within the EV ICD Pivotal Study (n = 247) reported statistically significant SF-12 improvements in physical QOL (45.4 ± 9.4 vs. 46.8 ± 9.1 respectively, p = .020) and no changes in mental QOL (49.3 ± 10.4 vs. 50.5 ± 9.7, p = .061). No differences were noted by sex, atrial fibrillation, or the experience of ICD shock. EV ICD patients reported better total FPAS patient acceptance of their ICD than TV-ICD or S-ICD patients using historical norms comparisons (80.4 ± 15.7 vs. 70.2 ± 17.8, p < .0001 for S-ICD and 73.0 ± 17.4, p = .004 for TV-ICD). CONCLUSION: The initial PROs for EV ICD patients indicated that patients had improvements in physical QOL from baseline to 6-month follow-up and markedly better overall acceptance of their ICD compared to a previous study with S-ICD and TV-ICD data. These initial results suggest that the EV ICD is evaluated positively by patients.


Assuntos
Desfibriladores Implantáveis , Humanos , Qualidade de Vida , Estudos Prospectivos , Inquéritos e Questionários , Medidas de Resultados Relatados pelo Paciente
10.
J Cardiovasc Electrophysiol ; 35(2): 230-237, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38047467

RESUMO

INTRODUCTION: The extravascular implantable cardioverter defibrillator (EV ICD) has extended projected battery longevity compared to the subcutaneous implantable cardioverter defibrillator (S-ICD). This study used modeling to characterize the need for generator changes, long-term complications, and overall costs for both the EV ICD and S-ICD in healthcare systems of various countries. METHODS: Battery longevity data were modeled using a Markov model from averages reported in device labeling for the S-ICD and with engineering estimates based on real life usage from EV ICD Pivotal Study patient data to introduce variability. Clinical demographic data were derived from published literature. The primary outcomes were defined as the number of generator replacement surgeries, complications, and total healthcare system costs due to battery depletion over the expected lifetime of patients receiving EV ICD or S-ICD therapy. RESULTS: Average modeled battery longevity was determined to be 7.3 years for the S-ICD versus 11.8 years for the EV ICD. The probability of a complication after a replacement procedure was 1.4%, with an operative mortality rate of 0.02%. The use of EV ICD was associated with 1.4-1.6 fewer replacements on average over an expected patient lifetime as compared to S-ICD and a 24.3%-26.0% reduction in cost. A one-way sensitivity analysis of the model for the US healthcare system found that use of an EV ICD resulted in a reduction in replacement surgeries of greater than 1 (1.1-1.6) along with five-figure cost savings in all scenarios ($18 602-$40 948). CONCLUSION: The longer projected battery life of the EV ICD has the potential to meaningfully reduce long-term morbidity and healthcare resources related to generator changes from the perspective of multiple diverse healthcare systems.


Assuntos
Desfibriladores Implantáveis , Humanos , Falha de Equipamento , Cardioversão Elétrica/efeitos adversos , Previsões , Redução de Custos
11.
Pacing Clin Electrophysiol ; 46(12): 1447-1454, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37997450

RESUMO

BACKGROUND: Cardiac implantable electronic devices (CIEDs) are routinely implanted using intravenous drugs for sedation. However, some patients are poor candidates for intravenous sedation. OBJECTIVE: We present a case series demonstrating the safety and efficacy of a novel, ultrasound-guided nerve block technique that allows for pre-pectoral CIED implantation. The targets are the supraclavicular nerve (SCN) and pectoral nerve (PECS1). METHODS: We enrolled 20 patients who were planned for new CIED implantation. Following US-localization of the SCN and PECS1, local anesthetic (LA) was instilled at least 30-60 min pre-procedure. Successful nerve block was determined if < 5 mL of intraprocedural LA was used, along with lack of sensation with skin and deep tissue pinprick. Optional sedation was offered to patients' pre-procedure if discomfort was reported. RESULTS: Seventeen patients (85%) had a successful periprocedural nerve block, with only three patients exceeding 5 mL of LA. SCN and PECS1 success occurred in 19 (95%) and 18 (90%) patients, respectively. The overall success of nerve block by fulfilling all the criteria was demonstrated in 17 out of 20 patients (85%). Patients who reported no pain (VAS score = 0) were distributed as follows: 13 patients (65%) in the immediate post-procedure interval, 18 patients (90%) at the 1 h post-implant interval, and 14 patients (70%) at the 24 h post- implant interval. The median cumulative VAS score was 0 (IQR = 0 - 1). There were no reported significant adverse effects. CONCLUSION: SCN and PECS1 nerve blocks are safe and effective for patients undergoing CIED implantation to minimize or eliminate the use of intravenous sedation.


Assuntos
Analgesia , Bloqueio Nervoso , Humanos , Projetos Piloto , Bloqueio Nervoso/métodos , Manejo da Dor , Anestésicos Locais/uso terapêutico
13.
JAMA Cardiol ; 8(5): 484-491, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-37017943

RESUMO

Importance: Cardiac implantable electronic device (CIED) infection is a potentially devastating complication with an estimated 12-month mortality of 15% to 30%. The association of the extent (localized or systemic) and timing of infection with all-cause mortality has not been established. Objective: To evaluate the association of the extent and timing of CIED infection with all-cause mortality. Design, Setting, and Participants: This prospective observational cohort study was conducted between December 1, 2012, and September 30, 2016, in 28 centers across Canada and the Netherlands. The study included 19 559 patients undergoing CIED procedures, 177 of whom developed an infection. Data were analyzed from April 5, 2021, to January 14, 2023. Exposures: Prospectively identified CIED infections. Main Outcomes and Measures: Time-dependent analysis of the timing (early [≤3 months] or delayed [3-12 months]) and extent (localized or systemic) of infection was performed to determine the risk of all-cause mortality associated with CIED infections. Results: Of 19 559 patients undergoing CIED procedures, 177 developed a CIED infection. The mean (SD) age was 68.7 (12.7) years, and 132 patients were male (74.6%). The cumulative incidence of infection was 0.6%, 0.7%, and 0.9% within 3, 6, and 12 months, respectively. Infection rates were highest in the first 3 months (0.21% per month), reducing significantly thereafter. Compared with patients who did not develop CIED infection, those with early localized infections were not at higher risk for all-cause mortality (no deaths at 30 days [0 of 74 patients]: adjusted hazard ratio [aHR], 0.64 [95% CI, 0.20-1.98]; P = .43). However, patients with early systemic and delayed localized infections had an approximately 3-fold increase in mortality (8.9% 30-day mortality [4 of 45 patients]: aHR, 2.88 [95% CI, 1.48-5.61]; P = .002; 8.8% 30-day mortality [3 of 34 patients]: aHR, 3.57 [95% CI, 1.33-9.57]; P = .01), increasing to a 9.3-fold risk of death for those with delayed systemic infections (21.7% 30-day mortality [5 of 23 patients]: aHR, 9.30 [95% CI, 3.82-22.65]; P < .001). Conclusions and Relevance: Findings suggest that CIED infections are most common within 3 months after the procedure. Early systemic infections and delayed localized infections are associated with increased mortality, with the highest risk for patients with delayed systemic infections. Early detection and treatment of CIED infections may be important in reducing mortality associated with this complication.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Humanos , Masculino , Idoso , Feminino , Desfibriladores Implantáveis/efeitos adversos , Estudos Prospectivos , Cardiopatias/etiologia , Canadá , Países Baixos
14.
N Engl J Med ; 387(14): 1292-1302, 2022 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-36036522

RESUMO

BACKGROUND: The extravascular implantable cardioverter-defibrillator (ICD) has a single lead implanted substernally to enable pause-prevention pacing, antitachycardia pacing, and defibrillation energy similar to that of transvenous ICDs. The safety and efficacy of extravascular ICDs are not yet known. METHODS: We conducted a prospective, single-group, nonrandomized, premarket global clinical study involving patients with a class I or IIa indication for an ICD, all of whom received an extravascular ICD system. The primary efficacy end point was successful defibrillation at implantation. The efficacy objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients with successful defibrillation was greater than 88%. The primary safety end point was freedom from major system- or procedure-related complications at 6 months. The safety objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients free from such complications was greater than 79%. RESULTS: A total of 356 patients were enrolled, 316 of whom had an implantation attempt. Among the 302 patients in whom ventricular arrhythmia could be induced and who completed the defibrillation testing protocol, the percentage of patients with successful defibrillation was 98.7% (lower boundary of the one-sided 97.5% confidence interval [CI], 96.6%; P<0.001 for the comparison with the performance goal of 88%); 299 of 316 patients (94.6%) were discharged with a working ICD system. The Kaplan-Meier estimate of the percentage of patients free from major system- or procedure-related complications at 6 months was 92.6% (lower boundary of the one-sided 97.5% CI, 89.0%; P<0.001 for the comparison with the performance goal of 79%). No major intraprocedural complications were reported. At 6 months, 25 major complications were observed, in 23 of 316 patients (7.3%). The success rate of antitachycardia pacing, as assessed with generalized estimating equations, was 50.8% (95% CI, 23.3 to 77.8). A total of 29 patients received 118 inappropriate shocks for 81 arrhythmic episodes. Eight systems were explanted without extravascular ICD replacement over the 10.6-month mean follow-up period. CONCLUSIONS: In this prospective global study, we found that extravascular ICDs were implanted safely and were able to detect and terminate induced ventricular arrhythmias at the time of implantation. (Funded by Medtronic; ClinicalTrials.gov number, NCT04060680.).


Assuntos
Desfibriladores Implantáveis , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Humanos , Estudos Prospectivos , Resultado do Tratamento
15.
JAMA Intern Med ; 182(10): 1091-1092, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35994257

RESUMO

This case report describes a patient in their 60s with atrial flutter ablation following admission to the hospital for heart failure exacerbation.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Eletrocardiografia , Humanos
16.
J Cardiovasc Electrophysiol ; 33(6): 1085-1095, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35478368

RESUMO

INTRODUCTION: The extravascular implantable cardioverter-defibrillato (EV ICD) system with substernal lead placement is a novel nontransvenous alternative to current commercially available ICD systems. The EV ICD provides defibrillation and pacing therapies without the potential long-term complications of endovascular lead placement but requires a new procedure for implantation with a safety profile under evaluation. METHODS: This paper summarizes the development of the EV ICD, including the preclinical and clinical evaluations that have contributed to the system and procedural refinements to date. RESULTS: Extensive preclinical research evaluations and four human clinical studies with >140 combined acute and chronic implants have enabled the development and refinement of the EV ICD system, currently in worldwide pivotal study. CONCLUSION: The EV ICD may represent a clinically valuable solution in protecting patients from sudden cardiac death while avoiding the long-term consequences of transvenous hardware. The EV ICD offers advantages over transvenous and subcutaneous systems by avoiding placement in the heart and vasculature; relative to subcutaneous systems, EV ICD requires less energy for defibrillation, enabling a smaller device, and provides pacing features such as antitachycardia and asystole pacing in a single system.


Assuntos
Desfibriladores Implantáveis , Parada Cardíaca , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Parada Cardíaca/diagnóstico , Parada Cardíaca/etiologia , Parada Cardíaca/terapia , Humanos
17.
Can J Cardiol ; 38(8): 1271-1276, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35346798

RESUMO

BACKGROUND: Patients with hemodynamically tolerated ventricular tachycardia (VT) and minimally reduced left ventricular ejection fraction (LVEF) remain a group that presents a prognostic and therapeutic dilemma. METHODS: We studied patients from our implanted cardioverter-defibrillator (ICD) database who received ICDs for hemodynamically tolerated VT and mildly reduced LVEF (36%-49%) at time of implant between May 2015 and December 2019. Time to appropriate ICD therapy was assessed. Clinical features associated with recurrent VT/ventricular fibrillation (VF) with ICD therapies were explored using binary logistic regression. RESULTS: Among 2037 ICDs placed between May 2015 and December 2019, 64 subjects met the inclusion criteria. The mean age of the study group was 68 ± 12 years, and 58 (90.6%) subjects were male. Average ejection fraction was 40% ± 4.4 (range 36%-49%). Twenty-two (34%) subjects received antitachycardia pacing (ATP) for VT at 229 ± 265 days after ICD placement. Fifteen (23%) subjects received appropriate ICD shocks 305 ± 321 days after implant. The rate of recurrent VT/VF among the 37 patients with ICD therapy was 195 ± 39 beats per minute (bpm). This was significantly more rapid than initial presenting VT rates before ICD placement (183 ± 27 bpm) (P = 0.048). Multivariate analysis showed no factors independently associated with recurrent VT/VF. CONCLUSIONS: Patients with mildly impaired LV function and hemodynamically tolerated VT receive appropriate ICD therapies over the 3 years following implant. This patient group warrants further investigation, as their recurrent VT/VF rates can be much more rapid, and 23% go on to receive appropriate ICD shocks.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas , Cardioversão Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Função Ventricular Esquerda
18.
Open Forum Infect Dis ; 8(11): ofab513, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34859113

RESUMO

BACKGROUND: The Prevention of Arrhythmia Device Infection Trial (PADIT) investigated whether intensification of perioperative prophylaxis could prevent cardiac implantable electronic device (CIED) infections. Compared with a single dose of cefazolin, the perioperative administration of cefazolin, vancomycin, bacitracin, and cephalexin did not significantly decrease the risk of infection. Our objective was to compare the microbiology of infections between study arms in PADIT. METHODS: This was a post hoc analysis. Differences between study arms in the microbiology of infections were assessed at the level of individual patients and at the level of microorganisms using the Fisher exact test. RESULTS: Overall, 209 microorganisms were reported from 177 patients. The most common microorganisms were coagulase-negative staphylococci (CoNS; 82/209 [39.2%]) and S. aureus (75/209 [35.9%]). There was a significantly lower proportion of CoNS in the incremental arm compared with the standard arm (30.1% vs 46.6%; P = .04). However, there was no significant difference between study arms in the frequency of recovery of other microorganisms. In terms of antimicrobial susceptibility, 26.5% of microorganisms were resistant to cefazolin. CoNS were more likely to be cefazolin-resistant in the incremental arm (52.2% vs 26.8%, respectively; P = .05). However, there was no difference between study arms in terms of infections in which the main pathogen was sensitive to cefazolin (77.8% vs 64.3%; P = .10) or vancomycin (90.8% vs 90.2%; P = .90). CONCLUSIONS: Intensification of the prophylaxis led to significant changes in the microbiology of infections, despite the absence of a decrease in the overall risk of infections. These findings provide important insight on the physiopathology of CIED infections. TRIAL REGISTRATION: NCT01002911.

19.
JAMA Netw Open ; 4(12): e2136830, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34854904

RESUMO

Importance: Persistently depressed left ventricular ejection fraction (LVEF) after myocardial infarction (MI) is associated with adverse prognosis and directs the use of evidence-based treatments to prevent sudden cardiac death and/or progressive heart failure. Objective: To assess adherence with guideline-recommended LVEF reassessment and to study the evolution of LVEF over 6 months of follow-up. Design, Setting, and Participants: This was a multicenter cohort study at Canadian academic and community hospitals with on-site cardiac catheterization services. Patients with type 1 acute MI and LVEF less than or equal to 45% during the index hospitalization were enrolled between January 2018 and August 2019 and were followed-up for 6 months. Data analysis was performed from May 2020 to September 2021. Exposures: Baseline clinical factors, in-hospital care and LVEF, and site-specific features. Main Outcomes and Measures: The main outcomes were receipt of repeat LVEF assessment by 6 months and the presence of a persistent LVEF reduction at 2 thresholds: LVEF less than or equal to 40%, prompting consideration of additional medical therapy for heart failure, or LVEF less than or equal to 35%, prompting referral for implanted cardioverter defibrillator in addition to medical therapy. Results: This study included 501 patients (mean [SD] age, 63.3 [13.0] years; 113 women [22.6%]). Overall, 370 patients (73.4%) presented with STEMI, and 454 (90.6%) had in-hospital revascularization. The median (IQR) baseline LVEF was 40% (34%-43%). Of 458 patients (91.4%) who completed the 6-month follow-up, 303 (66.2%; 95% CI, 61.7%-70.5%) had LVEF reassessment, with a range of 46.7% to 90.0% across sites (χ213 = 19.6; P = .11). Participants from community hospitals were more likely than those from academic hospitals to undergo LVEF reassessment (73.6% vs 63.2%; χ21 = 4.50; P = .03), as were those with worse LVEF at baseline. Follow-up LVEF improved by an absolute median (IQR) of 8% (3%-15%). However, 103 patients (34.1%) met the definitions of clinically relevant LVEF reduction, including 52 patients (17.2%) with LVEF less than or equal to 35% and 51 patients (16.9%) with LVEF of 35.1% to 40.0%. Conclusions and Relevance: In this cohort study, approximately 1 in 3 patients with at least mild LVEF reduction after acute MI did not undergo indicated LVEF reassessment within 6 months, suggesting that programs to improve the quality of post-MI care should include measures to ensure that indicated repeat cardiac imaging is performed. In those with follow-up imaging, clinically relevant persistent LVEF reduction was identified in more than one-third of patients.


Assuntos
Infarto do Miocárdio/terapia , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia , Canadá , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Prognóstico , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/sangue , Função Ventricular Esquerda
20.
Can J Cardiol ; 37(11): 1857-1860, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34571165

RESUMO

Physicians engaged in cardiovascular implantable electronic device (CIED)-related practice come from diverse training backgrounds with variable degrees of CIED implant training. The objective of the Canadian Heart Rhythm Society Task Force on CIED Implant Training was to establish a common structure and content for training programs in CIED implantation, related activities and maintenance of competency. This executive summary presents the essence of the report with key recommendations included, with the complete version made available in a linked supplement. The goals are to ensure that future generations of CIED implanters are better prepared for continuously evolving CIED practice and quality care for all Canadians.


Assuntos
Comitês Consultivos/estatística & dados numéricos , Cardiologia/educação , Desfibriladores Implantáveis , Educação de Pós-Graduação em Medicina/métodos , Marca-Passo Artificial , Médicos/normas , Sociedades Médicas , Arritmias Cardíacas/terapia , Canadá , Competência Clínica/normas , Cardioversão Elétrica/normas , Eletrônica , Guias como Assunto , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...